Supported protocols

More than 40 protocol adapters

From PLCs and meters to upstream systems and AV gear. Pick a protocol, enter address, port and period; each adapter runs on its own lane so a silent device never delays the rest.

PLC · Field devices

PLCs and controllers

As master, LinkVion reads and writes devices. As slave, it stands in as a device and serves values to an upstream PLC or HMI.

PLC protocols
ProtocolModels · framingRoleNotes
ModbusTCP · RTU · ASCIIMaster · slaveBatch reads for many tags; data type, word order and unit ID settings.
Mitsubishi MC protocolQ · iQ-R · iQ-FMaster · slave10,000 words per cycle in 16 ms (CM4 loopback).
Mitsubishi SLMP3E · 4E (binary, ASCII)
LS XGT · XGIMaster · slave
Siemens S7S7-300 · 400 · 1200 · 1500Master · slave
Omron FINSCS · CJ · NJ · NXMaster · slave
Keyence KVKV-5000 · 7500 · 8000Master · slave
Panasonic MEWTOCOLFP-X · FP7Master · slave
CIMON PLCMaster · slave
EtherNet/IPCIP scanner · adapterMaster · slaveIn the LinkVion Box (CM4) package.
DNP3MasterRemote monitoring for power and water.
IEC 60870-5-104Master · slave
BACnet/IPClientNot yet field-verified; not in the LinkVion Box package.

IT · Upstream

Upstream and cloud integration

Upstream protocols
ProtocolRoleNotes
OPC UAClient · serverThe server publishes tags as nodes with certificates, trust list, users and per-node permissions. The client reads numeric and boolean nodes.
MQTT 3.1.1 · 5Subscribe · publish propertiesChoose MQTT 5 per connection (user properties, will, retained messages, diagnostics).
REST APIRead · write · live streamTag read and write, settings, live value stream (SSE, authenticated).
Web requestsHTTPCall external REST/HTTP APIs; admin-configured with an allow list.
CoAPClient · server
Kafka · ZeroMQReceive
SNMPManager
SNTPClient · serverSync the device clock and serve time to field devices.
Email · TelegramSend noticesChoose channels per alarm rule. Email uses SMTPS or STARTTLS with certificate checks; Telegram can also be sent from scripts (release after 0.1.0.24).
MCPServerExternal AI agents use tags, alarms, settings and screen design as tools, within a configured scope.

AV · Lighting · instruments

Power, lighting, show control, cameras

Exhibitions, landscape lighting and control rooms: devices beyond PLCs use the same tags.

AV and lighting protocols
Protocol · deviceWhat it does
PJLinkProjector and display power, input, mute, lamp hours, errors
Wake-on-LANWake PCs and displays
SNMP PDU · display templatesOutlet control, display control templates
Art-Net 4 · sACN (E1.31)Lighting output at 44 Hz: fixture profiles, patch, scenes, fades, cues. Art-Net input merge
OSCReceive (address pattern → tag), send (tag → address), allow list
CamerasIP, USB, RTSP (H.264), depending on platform; up to 6 RTSP cameras on the LinkVion Box
SCPIStandard instrument commands
Tower lampsSignal tower control

Power, lighting and OSC were tested against simulators; field verification with real equipment is still to come.

Not on the list?

Two ways to add a protocol without code

  • Declarative adapter — one spec file (meta.json) adds a protocol to the connection list without rebuilding the gateway.
  • User-defined protocol — define requests and replies in a command table, or start from a template.
  • The connection list shows as available only the packages actually installed (this can differ by platform).
Ask about your equipment
New connection dialog — choosing a protocol
Product screen: choosing a protocol in New connection.